mirror of
https://github.com/python/cpython.git
synced 2024-11-25 09:39:56 +01:00
853163d3b5
Add the ability to enable/disable the GIL at runtime, and use that in the C module loading code. We can't know before running a module init function if it supports free-threading, so the GIL is temporarily enabled before doing so. If the module declares support for running without the GIL, the GIL is later disabled. Otherwise, the GIL is permanently enabled, and will never be disabled again for the life of the current interpreter.
385 lines
11 KiB
C++
385 lines
11 KiB
C++
//
|
|
// Helper library for querying WMI using its COM-based query API.
|
|
//
|
|
// Copyright (c) Microsoft Corporation
|
|
// Licensed to PSF under a contributor agreement
|
|
//
|
|
|
|
// Version history
|
|
// 2022-08: Initial contribution (Steve Dower)
|
|
|
|
// clinic/_wmimodule.cpp.h uses internal pycore_modsupport.h API
|
|
#ifndef Py_BUILD_CORE_BUILTIN
|
|
# define Py_BUILD_CORE_MODULE 1
|
|
#endif
|
|
|
|
#define _WIN32_DCOM
|
|
#include <Windows.h>
|
|
#include <comdef.h>
|
|
#include <Wbemidl.h>
|
|
#include <propvarutil.h>
|
|
|
|
#include <Python.h>
|
|
|
|
|
|
#if _MSVC_LANG >= 202002L
|
|
// We can use clinic directly when the C++ compiler supports C++20
|
|
#include "clinic/_wmimodule.cpp.h"
|
|
#else
|
|
// Cannot use clinic because of missing C++20 support, so create a simpler
|
|
// API instead. This won't impact releases, so fine to omit the docstring.
|
|
static PyObject *_wmi_exec_query_impl(PyObject *module, PyObject *query);
|
|
#define _WMI_EXEC_QUERY_METHODDEF {"exec_query", _wmi_exec_query_impl, METH_O, NULL},
|
|
#endif
|
|
|
|
|
|
/*[clinic input]
|
|
module _wmi
|
|
[clinic start generated code]*/
|
|
/*[clinic end generated code: output=da39a3ee5e6b4b0d input=7ca95dad1453d10d]*/
|
|
|
|
|
|
|
|
struct _query_data {
|
|
LPCWSTR query;
|
|
HANDLE writePipe;
|
|
HANDLE readPipe;
|
|
HANDLE initEvent;
|
|
HANDLE connectEvent;
|
|
};
|
|
|
|
|
|
static DWORD WINAPI
|
|
_query_thread(LPVOID param)
|
|
{
|
|
IWbemLocator *locator = NULL;
|
|
IWbemServices *services = NULL;
|
|
IEnumWbemClassObject* enumerator = NULL;
|
|
BSTR bstrQuery = NULL;
|
|
struct _query_data *data = (struct _query_data*)param;
|
|
|
|
HRESULT hr = CoInitializeEx(nullptr, COINIT_APARTMENTTHREADED);
|
|
if (FAILED(hr)) {
|
|
CloseHandle(data->writePipe);
|
|
return (DWORD)hr;
|
|
}
|
|
|
|
hr = CoInitializeSecurity(
|
|
NULL, -1, NULL, NULL,
|
|
RPC_C_AUTHN_LEVEL_DEFAULT,
|
|
RPC_C_IMP_LEVEL_IMPERSONATE,
|
|
NULL, EOAC_NONE, NULL
|
|
);
|
|
// gh-96684: CoInitializeSecurity will fail if another part of the app has
|
|
// already called it. Hopefully they passed lenient enough settings that we
|
|
// can complete the WMI query, so keep going.
|
|
if (hr == RPC_E_TOO_LATE) {
|
|
hr = 0;
|
|
}
|
|
if (SUCCEEDED(hr)) {
|
|
hr = CoCreateInstance(
|
|
CLSID_WbemLocator, 0, CLSCTX_INPROC_SERVER,
|
|
IID_IWbemLocator, (LPVOID *)&locator
|
|
);
|
|
}
|
|
if (SUCCEEDED(hr) && !SetEvent(data->initEvent)) {
|
|
hr = HRESULT_FROM_WIN32(GetLastError());
|
|
}
|
|
if (SUCCEEDED(hr)) {
|
|
hr = locator->ConnectServer(
|
|
bstr_t(L"ROOT\\CIMV2"),
|
|
NULL, NULL, 0, NULL, 0, 0, &services
|
|
);
|
|
}
|
|
if (SUCCEEDED(hr) && !SetEvent(data->connectEvent)) {
|
|
hr = HRESULT_FROM_WIN32(GetLastError());
|
|
}
|
|
if (SUCCEEDED(hr)) {
|
|
hr = CoSetProxyBlanket(
|
|
services, RPC_C_AUTHN_WINNT, RPC_C_AUTHZ_NONE, NULL,
|
|
RPC_C_AUTHN_LEVEL_CALL, RPC_C_IMP_LEVEL_IMPERSONATE,
|
|
NULL, EOAC_NONE
|
|
);
|
|
}
|
|
if (SUCCEEDED(hr)) {
|
|
bstrQuery = SysAllocString(data->query);
|
|
if (!bstrQuery) {
|
|
hr = HRESULT_FROM_WIN32(ERROR_NOT_ENOUGH_MEMORY);
|
|
}
|
|
}
|
|
if (SUCCEEDED(hr)) {
|
|
hr = services->ExecQuery(
|
|
bstr_t("WQL"),
|
|
bstrQuery,
|
|
WBEM_FLAG_FORWARD_ONLY | WBEM_FLAG_RETURN_IMMEDIATELY,
|
|
NULL,
|
|
&enumerator
|
|
);
|
|
}
|
|
|
|
// Okay, after all that, at this stage we should have an enumerator
|
|
// to the query results and can start writing them to the pipe!
|
|
IWbemClassObject *value = NULL;
|
|
int startOfEnum = TRUE;
|
|
int endOfEnum = FALSE;
|
|
while (SUCCEEDED(hr) && !endOfEnum) {
|
|
ULONG got = 0;
|
|
DWORD written;
|
|
hr = enumerator->Next(WBEM_INFINITE, 1, &value, &got);
|
|
if (hr == WBEM_S_FALSE) {
|
|
// Could be at the end, but still got a result this time
|
|
endOfEnum = TRUE;
|
|
hr = 0;
|
|
break;
|
|
}
|
|
if (FAILED(hr) || got != 1 || !value) {
|
|
continue;
|
|
}
|
|
if (!startOfEnum && !WriteFile(data->writePipe, (LPVOID)L"\0", 2, &written, NULL)) {
|
|
hr = HRESULT_FROM_WIN32(GetLastError());
|
|
break;
|
|
}
|
|
startOfEnum = FALSE;
|
|
// Okay, now we have each resulting object it's time to
|
|
// enumerate its members
|
|
hr = value->BeginEnumeration(0);
|
|
if (FAILED(hr)) {
|
|
value->Release();
|
|
break;
|
|
}
|
|
while (SUCCEEDED(hr)) {
|
|
BSTR propName;
|
|
VARIANT propValue;
|
|
long flavor;
|
|
hr = value->Next(0, &propName, &propValue, NULL, &flavor);
|
|
if (hr == WBEM_S_NO_MORE_DATA) {
|
|
hr = 0;
|
|
break;
|
|
}
|
|
if (SUCCEEDED(hr) && (flavor & WBEM_FLAVOR_MASK_ORIGIN) != WBEM_FLAVOR_ORIGIN_SYSTEM) {
|
|
WCHAR propStr[8192];
|
|
hr = VariantToString(propValue, propStr, sizeof(propStr) / sizeof(propStr[0]));
|
|
if (SUCCEEDED(hr)) {
|
|
DWORD cbStr1, cbStr2;
|
|
cbStr1 = (DWORD)(wcslen(propName) * sizeof(propName[0]));
|
|
cbStr2 = (DWORD)(wcslen(propStr) * sizeof(propStr[0]));
|
|
if (!WriteFile(data->writePipe, propName, cbStr1, &written, NULL) ||
|
|
!WriteFile(data->writePipe, (LPVOID)L"=", 2, &written, NULL) ||
|
|
!WriteFile(data->writePipe, propStr, cbStr2, &written, NULL) ||
|
|
!WriteFile(data->writePipe, (LPVOID)L"\0", 2, &written, NULL)
|
|
) {
|
|
hr = HRESULT_FROM_WIN32(GetLastError());
|
|
}
|
|
}
|
|
VariantClear(&propValue);
|
|
SysFreeString(propName);
|
|
}
|
|
}
|
|
value->EndEnumeration();
|
|
value->Release();
|
|
}
|
|
|
|
if (bstrQuery) {
|
|
SysFreeString(bstrQuery);
|
|
}
|
|
if (enumerator) {
|
|
enumerator->Release();
|
|
}
|
|
if (services) {
|
|
services->Release();
|
|
}
|
|
if (locator) {
|
|
locator->Release();
|
|
}
|
|
CoUninitialize();
|
|
CloseHandle(data->writePipe);
|
|
return (DWORD)hr;
|
|
}
|
|
|
|
|
|
static DWORD
|
|
wait_event(HANDLE event, DWORD timeout)
|
|
{
|
|
DWORD err = 0;
|
|
switch (WaitForSingleObject(event, timeout)) {
|
|
case WAIT_OBJECT_0:
|
|
break;
|
|
case WAIT_TIMEOUT:
|
|
err = WAIT_TIMEOUT;
|
|
break;
|
|
default:
|
|
err = GetLastError();
|
|
break;
|
|
}
|
|
return err;
|
|
}
|
|
|
|
|
|
/*[clinic input]
|
|
_wmi.exec_query
|
|
|
|
query: unicode
|
|
|
|
Runs a WMI query against the local machine.
|
|
|
|
This returns a single string with 'name=value' pairs in a flat array separated
|
|
by null characters.
|
|
[clinic start generated code]*/
|
|
|
|
static PyObject *
|
|
_wmi_exec_query_impl(PyObject *module, PyObject *query)
|
|
/*[clinic end generated code: output=a62303d5bb5e003f input=48d2d0a1e1a7e3c2]*/
|
|
|
|
/*[clinic end generated code]*/
|
|
{
|
|
PyObject *result = NULL;
|
|
HANDLE hThread = NULL;
|
|
int err = 0;
|
|
WCHAR buffer[8192];
|
|
DWORD offset = 0;
|
|
DWORD bytesRead;
|
|
struct _query_data data = {0};
|
|
|
|
if (PySys_Audit("_wmi.exec_query", "O", query) < 0) {
|
|
return NULL;
|
|
}
|
|
|
|
data.query = PyUnicode_AsWideCharString(query, NULL);
|
|
if (!data.query) {
|
|
return NULL;
|
|
}
|
|
|
|
if (0 != _wcsnicmp(data.query, L"select ", 7)) {
|
|
PyMem_Free((void *)data.query);
|
|
PyErr_SetString(PyExc_ValueError, "only SELECT queries are supported");
|
|
return NULL;
|
|
}
|
|
|
|
Py_BEGIN_ALLOW_THREADS
|
|
|
|
data.initEvent = CreateEvent(NULL, TRUE, FALSE, NULL);
|
|
data.connectEvent = CreateEvent(NULL, TRUE, FALSE, NULL);
|
|
if (!data.initEvent || !data.connectEvent ||
|
|
!CreatePipe(&data.readPipe, &data.writePipe, NULL, 0))
|
|
{
|
|
err = GetLastError();
|
|
} else {
|
|
hThread = CreateThread(NULL, 0, _query_thread, (LPVOID*)&data, 0, NULL);
|
|
if (!hThread) {
|
|
err = GetLastError();
|
|
// Normally the thread proc closes this handle, but since we never started
|
|
// we need to close it here.
|
|
CloseHandle(data.writePipe);
|
|
}
|
|
}
|
|
|
|
// gh-112278: If current user doesn't have permission to query the WMI, the
|
|
// function IWbemLocator::ConnectServer will hang for 5 seconds, and there
|
|
// is no way to specify the timeout. So we use an Event object to simulate
|
|
// a timeout. The initEvent will be set after COM initialization, it will
|
|
// take a longer time when first initialized. The connectEvent will be set
|
|
// after connected to WMI.
|
|
if (!err) {
|
|
err = wait_event(data.initEvent, 1000);
|
|
if (!err) {
|
|
err = wait_event(data.connectEvent, 100);
|
|
}
|
|
}
|
|
|
|
while (!err) {
|
|
if (ReadFile(
|
|
data.readPipe,
|
|
(LPVOID)&buffer[offset / sizeof(buffer[0])],
|
|
sizeof(buffer) - offset,
|
|
&bytesRead,
|
|
NULL
|
|
)) {
|
|
offset += bytesRead;
|
|
if (offset >= sizeof(buffer)) {
|
|
err = ERROR_MORE_DATA;
|
|
}
|
|
} else {
|
|
err = GetLastError();
|
|
}
|
|
}
|
|
|
|
if (data.readPipe) {
|
|
CloseHandle(data.readPipe);
|
|
}
|
|
|
|
if (hThread) {
|
|
// Allow the thread some time to clean up
|
|
int thread_err;
|
|
switch (WaitForSingleObject(hThread, 100)) {
|
|
case WAIT_OBJECT_0:
|
|
// Thread ended cleanly
|
|
if (!GetExitCodeThread(hThread, (LPDWORD)&thread_err)) {
|
|
thread_err = GetLastError();
|
|
}
|
|
break;
|
|
case WAIT_TIMEOUT:
|
|
// Probably stuck - there's not much we can do, unfortunately
|
|
thread_err = WAIT_TIMEOUT;
|
|
break;
|
|
default:
|
|
thread_err = GetLastError();
|
|
break;
|
|
}
|
|
// An error on our side is more likely to be relevant than one from
|
|
// the thread, but if we don't have one on our side we'll take theirs.
|
|
if (err == 0 || err == ERROR_BROKEN_PIPE) {
|
|
err = thread_err;
|
|
}
|
|
|
|
CloseHandle(hThread);
|
|
}
|
|
|
|
CloseHandle(data.initEvent);
|
|
CloseHandle(data.connectEvent);
|
|
hThread = NULL;
|
|
|
|
Py_END_ALLOW_THREADS
|
|
|
|
PyMem_Free((void *)data.query);
|
|
|
|
if (err == ERROR_MORE_DATA) {
|
|
PyErr_Format(PyExc_OSError, "Query returns more than %zd characters", Py_ARRAY_LENGTH(buffer));
|
|
return NULL;
|
|
} else if (err) {
|
|
PyErr_SetFromWindowsErr(err);
|
|
return NULL;
|
|
}
|
|
|
|
if (!offset) {
|
|
return PyUnicode_FromStringAndSize(NULL, 0);
|
|
}
|
|
return PyUnicode_FromWideChar(buffer, offset / sizeof(buffer[0]) - 1);
|
|
}
|
|
|
|
|
|
static PyMethodDef wmi_functions[] = {
|
|
_WMI_EXEC_QUERY_METHODDEF
|
|
{ NULL, NULL, 0, NULL }
|
|
};
|
|
|
|
static PyModuleDef_Slot wmi_slots[] = {
|
|
{Py_mod_gil, Py_MOD_GIL_NOT_USED},
|
|
{0, NULL},
|
|
};
|
|
|
|
static PyModuleDef wmi_def = {
|
|
PyModuleDef_HEAD_INIT,
|
|
"_wmi",
|
|
NULL, // doc
|
|
0, // m_size
|
|
wmi_functions, // m_methods
|
|
wmi_slots, // m_slots
|
|
};
|
|
|
|
extern "C" {
|
|
PyMODINIT_FUNC PyInit__wmi(void)
|
|
{
|
|
return PyModuleDef_Init(&wmi_def);
|
|
}
|
|
}
|