gh-115832: Fix instrumentation version mismatch during interpreter shutdown (#115856)
A previous commit introduced a bug to `interpreter_clear()`: it set `interp->ceval.instrumentation_version` to 0, without making the corresponding change to `tstate->eval_breaker` (which holds a thread-local copy of the version). After this happens, Python code can still run due to object finalizers during a GC, and the version check in bytecodes.c will see a different result than the one in instrumentation.c causing an infinite loop. The fix itself is straightforward: clear `tstate->eval_breaker` when clearing `interp->ceval.instrumentation_version`.
This commit is contained in:
parent
15dc2979bc
commit
0adfa8482d
30
Lib/test/_test_monitoring_shutdown.py
Normal file
30
Lib/test/_test_monitoring_shutdown.py
Normal file
@ -0,0 +1,30 @@
|
||||
#!/usr/bin/env python3
|
||||
|
||||
# gh-115832: An object destructor running during the final GC of interpreter
|
||||
# shutdown triggered an infinite loop in the instrumentation code.
|
||||
|
||||
import sys
|
||||
|
||||
class CallableCycle:
|
||||
def __init__(self):
|
||||
self._cycle = self
|
||||
|
||||
def __del__(self):
|
||||
pass
|
||||
|
||||
def __call__(self, code, instruction_offset):
|
||||
pass
|
||||
|
||||
def tracefunc(frame, event, arg):
|
||||
pass
|
||||
|
||||
def main():
|
||||
tool_id = sys.monitoring.PROFILER_ID
|
||||
event_id = sys.monitoring.events.PY_START
|
||||
|
||||
sys.monitoring.use_tool_id(tool_id, "test profiler")
|
||||
sys.monitoring.set_events(tool_id, event_id)
|
||||
sys.monitoring.register_callback(tool_id, event_id, CallableCycle())
|
||||
|
||||
if __name__ == "__main__":
|
||||
sys.exit(main())
|
@ -9,7 +9,8 @@ import textwrap
|
||||
import types
|
||||
import unittest
|
||||
import asyncio
|
||||
from test.support import requires_specialization
|
||||
from test import support
|
||||
from test.support import requires_specialization, script_helper
|
||||
|
||||
PAIR = (0,1)
|
||||
|
||||
@ -1858,3 +1859,12 @@ class TestTier2Optimizer(CheckEvents):
|
||||
sys.monitoring.register_callback(TEST_TOOL, E.LINE, None)
|
||||
sys.monitoring.set_events(TEST_TOOL, 0)
|
||||
self.assertGreater(len(events), 250)
|
||||
|
||||
class TestMonitoringAtShutdown(unittest.TestCase):
|
||||
|
||||
def test_monitoring_live_at_shutdown(self):
|
||||
# gh-115832: An object destructor running during the final GC of
|
||||
# interpreter shutdown triggered an infinite loop in the
|
||||
# instrumentation code.
|
||||
script = support.findfile("_test_monitoring_shutdown.py")
|
||||
script_helper.run_test_script(script)
|
||||
|
@ -891,8 +891,16 @@ static inline int most_significant_bit(uint8_t bits) {
|
||||
static uint32_t
|
||||
global_version(PyInterpreterState *interp)
|
||||
{
|
||||
return (uint32_t)_Py_atomic_load_uintptr_relaxed(
|
||||
uint32_t version = (uint32_t)_Py_atomic_load_uintptr_relaxed(
|
||||
&interp->ceval.instrumentation_version);
|
||||
#ifdef Py_DEBUG
|
||||
PyThreadState *tstate = _PyThreadState_GET();
|
||||
uint32_t thread_version =
|
||||
(uint32_t)(_Py_atomic_load_uintptr_relaxed(&tstate->eval_breaker) &
|
||||
~_PY_EVAL_EVENTS_MASK);
|
||||
assert(thread_version == version);
|
||||
#endif
|
||||
return version;
|
||||
}
|
||||
|
||||
/* Atomically set the given version in the given location, without touching
|
||||
|
@ -795,7 +795,10 @@ interpreter_clear(PyInterpreterState *interp, PyThreadState *tstate)
|
||||
|
||||
Py_CLEAR(interp->audit_hooks);
|
||||
|
||||
// At this time, all the threads should be cleared so we don't need atomic
|
||||
// operations for instrumentation_version or eval_breaker.
|
||||
interp->ceval.instrumentation_version = 0;
|
||||
tstate->eval_breaker = 0;
|
||||
|
||||
for (int i = 0; i < _PY_MONITORING_UNGROUPED_EVENTS; i++) {
|
||||
interp->monitors.tools[i] = 0;
|
||||
|
Loading…